![Amada MD-A8000B-05 Series Operation Manual Download Page 66](http://html1.mh-extra.com/html/amada/md-a8000b-05-series/md-a8000b-05-series_operation-manual_2915803066.webp)
MD Series
9. External Communication Function
9-8
At the occurrence of fault
In case of one fault
Data strings: E: 01, 01, 06 [CR][LF]
A B C D E
Ex.) E: 01,01,06[CR][LF]
In case of five faults
Data strings: E: 01, 01, 06, 07, 08, 09, 10 [CR][LF]
A B C D D D D D E
Ex.) E: 01,01,06,07,08,09,10[CR][LF]
Item
Character
string
Content Range
A
E:
Fault send code
E: (fixed)
B
**,
Device No.
01 to 31
C
**,
Schedule No.
01 to 31
D **
*1
Fault code
01 to 20
E
[CR][LF]
CR, LF code
0DH 0AH (fixed)
*1: Up to five fault codes are output. If two or more fault codes exist, the codes are separated
with “,”. If no fault exists, E00 is output.