
MD Series
9. External Communication Function
9-2
(2) Single-Directional Communication B Mode
(COMMUNICATION MODE on STATUS Screen is B MODE)
1-step welding (When SCHEDULE MODE on the STATUS screen is set to SINGLE)
Data strings: M: W1, 01, 5.00, 4.50, 4.50, 4.00, 18.0, 0.89 [CR]
A B C D E F G H I J
Ex.) M: W1,01,5.00,4.50,4.50,4.00,18.0,0.89[CR]
Item
Character
string
Content Range
A
M:
Monitor value sending code
M: (fixed)
B
W1,
Welding code (1-step welding)
W1 (fixed)
C
**,
Schedule No.
01 to 31
D
***,
*1
WELD: Current
Peak value
000 to 999[A] ,!!!!
*3
*.**,
*2
0.00 to 9.99[kA] ,!!!!
*3
E
***,
*1
Average value
000 to 999[A] ,!!!!
*3
*.**,
*2
0.00 to 9.99[kA] ,!!!!
*3
F *.**,
WELD: Voltage
Peak value
0.00 to 9.99[V] ,!!!!
*3
G
*.**,
Average value
0.00 to 9.99[V] ,!!!!
*3
H
*.**,
*1
WELD: Power average value
0.00 to 9.99[kW] ,!!!!
*3
**.*,
*2
00.0 to 99.9[kW] ,!!!!
*3
I
*.**
WELD: Resistance average value
0.00 to 9.99[m
Ω
] ,!!!!
*3
J [CR]
CR
code
0DH
(fixed)
*1: When CURRENT RANGE on the STATUS screen is ***A.
*2: When CURRENT RANGE on the STATUS screen is *.**kA.
*3: When the value exceeds the display range.
Summary of Contents for MD-A8000B-05 Series
Page 95: ......