MD Series
9. External Communication Function
9-14
3) Specified code No.: S02 (SCHEDULE screen)
Used when SCHEDULE MODE on the STATUS screen is DOUBLE.
In case of SINGLE, use Specified code No. S01.
Data strings: When reading Device No. 01 and Schedule No. 008
Host PC -> MD series
#01R008S02[CR][LF]
MD series -> Host PC
!01008S02: 0100, 1.00, 5.00, 1.00, 2.00, 1.00, 4.00, 1.00, 100, kA,
A B
C D
E F G
H I
J
2.00, 3.00, 1.00, 1.50 [CR][LF]
K L
M N
Item
Character
string
Content Range
Increment/
Decrement
A
****,
SQ: Squeeze time
0000 to 9999[ms]
1
B
*.**,
*1
U1: Upslope 1 time
0.00 to 9.99[ms]
0.01
**.*,
*2
00.0 to 99.9[ms]
0.1
C
*.**,
*1
W1: Weld 1 time
0.00 to 9.99[ms]
0.01
**.*,
*2
00.0 to 99.9[ms]
0.1
D
*.**,
*1
D1: Downslope 1 time
0.00 to 9.99[ms]
0.01
**.*,
*2
00.0 to 99.9[ms]
0.1
E
*.**,
*1
CL: Cool time
0.00 to 9.99[ms]
0.01
**.*,
*2
00.0 to 49.9[ms]
0.1
F
*.**,
*1
U2: Upslope 2 time
0.00 to 9.99[ms]
0.01
**.*,
*2
00.0 to 99.9[ms]
0.1
G
*.**,
*1
W2: Weld 2 time
0.00 to 9.99[ms]
0.01
**.*,
*2
00.0 to 99.9[ms]
0.1
H
*.**,
*1
D2: Downslope 2 time
0.00 to 9.99[ms]
0.01
**.*,
*2
00.0 to 99.9[ms]
0.1
I
***,
HD: Hold time
000 to 999[ms]
1
J **,
Unit of current value
_A: Current value in A
(
_
indicates space)
kA: Current value in kA
A or kA
-
K
****,
*3
W1: Weld 1 current
0000 to 0999[A]
*5
1
*.**,
*4
0.00 to 9.99[kA]
*5
0.01
L
****,
*3
W2: Weld 2 current
0000 to 0999[A]
*5
1
*.**,
*4
0.00 to 9.99[kA]
*5
0.01
M
*.**,
W1: Weld 1 voltage
0.00 to 9.99[V]
0.01
N
*.**
W2: Weld 2 voltage
0.00 to 9.99[V]
0.01
*1: When WELD TIME on the STATUS screen is NORMAL.