Setting
Unit
Minimum - Maximum
Default/Advised
Roller drive fast.
%
0-100
60
Set the speed of the bale on the wrapping table
during full speed wrapping.
This adjustment is only shown and adjustable when
Roller control is "OFF".
Setting
Unit
Minimum - Maximum
Default/Advised
Roller drive slow.
%
0-100
35
Set the speed of the bale on the wrapping table
during the start of wrapping.
This adjustment is only shown and adjustable when
Roller control is "OFF".
Setting
Unit
Minimum - Maximum
Default/Advised
Film break alarm.
-
"OFF" / "Stop at 1st" /
"Stop at 2nd"
"Stop at 1st"
• "Stop at 1st" - Stop and give an alarm when
damage occurs to 1 film
• "Stop at 2nd" - Stop and give an alarm when
damage occurs to 2 films (the wrapper will
continue with damage to 1 film)
• "Off" - Do not stop and give an alarm when
damage occurs to a film.
Use the values in the table given as a guide.
Film roll width
Film overlap
Film layers
Roller drive fast
Revolutions per
bale
500 mm
55%
2
55%
6
4
55%
11
6
55%
16
70%
3
40%
9
6
40%
16
750 mm
55%
2
70%
5
4
70%
8
6
70%
12
70%
3
55%
6
6
55%
12
2. Introduction
56
Baler Wrapper Combination
4900.LE.EN01
Summary of Contents for LELY RPC 130 F
Page 2: ......
Page 8: ...Table of contents 8 Baler Wrapper Combination 4900 LE EN01...
Page 32: ...1 Safety 32 Baler Wrapper Combination 4900 LE EN01...
Page 34: ...Table of contents 34 Baler Wrapper Combination 4900 LE EN01...
Page 110: ...3 Operation 110 Baler Wrapper Combination 4900 LE EN01...
Page 112: ...Table of contents 112 Baler Wrapper Combination 4900 LE EN01...
Page 122: ...Danger Zones page 31 4 Maintenance and Lubrication 122 Baler Wrapper Combination 4900 LE EN01...
Page 148: ...Table of contents 148 Baler Wrapper Combination 4900 LE EN01...
Page 158: ...Table of contents 158 Baler Wrapper Combination 4900 LE EN01...
Page 164: ...6 Specifications 164 Baler Wrapper Combination 4900 LE EN01...
Page 167: ......
Page 168: ...AGCO Corporation 2018 All rights reserved 4900 LE EN01 English May 2018...