ZEISS
5 First Operating Steps | 5.4 Acquiring an Image
5.4.9 Acquiring an Image
Info
The following procedure describes the best way to quickly obtain an image without the con-
trol panel. You can also use the control panel to adjust aperture alignment, magnification/fo-
cus and brightness/contrast.
The following procedure describes how to acquire an image in high vacuum (HV) mode.
For further information on pressure and operating modes, refer to
Info
You can also use the Automated or Semi-automated Functions to help you with these tasks.
This procedure consists of the following steps:
1.
Selecting the Optibeam Mode and the Apertures [
2.
Setting EHT and Probe Current [
3.
4.
5.
6.
Setting a Long Working Distance [
7.
Adjusting Brightness and Contrast [
8.
Visualizing Details on the Specimen Surface [
5.4.9.1 Selecting the Optibeam Mode and the Apertures
Procedure
1. In the SEM Controls panel, select the
Apertures
tab.
2. From the
Optibeam
drop-down list, select
Optibeam = Resolution
.
à
The Optibeam mode is set.
3. Click
Select Aperture
and select the
EasyVP Aperture
.
à
The pressure-limiting aperture is set.
Instruction Manual ZEISS EVO | en-US | Rev. 10 | 354706-0780-006