9-24
9-25
Chapter
9
TROUBLESHOOTING
6.26 : No sufficient memory for OUT
Code
: &H061A
Meaning/Cause
: Failed to run an OUT command due to insufficient memory
caused by multiple OUT commands that were run in
succession.
Action
: Check the number of OUT commands. The maximum number
of OUT commands that can be run in parallel is 16.
6.27 : PATH without SET
Code
: &H061B
Meaning/Cause
: Any of PATH L, PATH C and PATH END was executed without
executing PATH SET.
Action
: First execute PATH SET when setting a path.
6.28 : PATH without END
Code
: &H061C
Meaning/Cause
: PATH START was executed without executing PATH END.
Action
: Execute PATH END to end the path setting and then execute
PATH START.
6.29 : No PATH data
Code
: &H061D
Meaning/Cause
: No path is set for PATH motion.
Action
: Set a path with PATH L and PATH C. The previously set path
will be lost in the following cases:
• When PATH SET is executed.
• When program is changed.
• When program is reset.
• When controller power is turned off.
6.30 : Too many PATH data
Code
: &H061E
Meaning/Cause
: The number of PATH motion paths has exceeded 300.
Action
: Reduce the number of PATH motion paths to 300 or less in
total of straight lines and circular arcs.
6.31 : Not PATH start position
Code
: &H061F
Meaning/Cause
: Robot's current position is not the start position of PATH
motion.
Action
: Move the robot to the start position specified with PATH SET
and then execute PATH START.
[ 6] Robot language execution errors
Содержание RCX222
Страница 1: ...RCX222 EUR2153130 E99 Ver 1 30 Userʼs Manual YAMAHA 2 AXIS ROBOT CONTROLLER ...
Страница 2: ......
Страница 14: ......
Страница 43: ......
Страница 46: ......
Страница 50: ...4 MEMO ...
Страница 51: ...Chapter 1 USING THE ROBOT SAFELY Contents 1 Operating environment 1 1 ...
Страница 52: ......
Страница 56: ......
Страница 98: ......
Страница 388: ......
Страница 412: ...5 24 MEMO ...
Страница 414: ......
Страница 430: ......
Страница 442: ......
Страница 450: ...8 8 MEMO ...
Страница 452: ......
Страница 523: ......