4-248
Chapter
4
OPERA
TION
4-249
12. "SYSTEM" mode
Valid keys and submenu descriptions in "SYSTEM>INIT>MEMORY" mode are shown
below.
Valid keys
Menu
Function
F1
PROGRAM Deletes the program data.
F2
POINT
Deletes the point data.
F3
SHIFT
Initializes the shift coordinate data.
F4
HAND
Initializes the hand definition data.
F5
ALL
Deletes/initializes all data (program, point, shift
coordinates, hand definition, pallet definition, point
comment).
F6
PALLET
Deletes the pallet definition data.
F7
COMMENT Deletes the point comment data.
12.4.3
Initializing the communication parameters
To initialize the communication parameters, proceed as follows.
[Procedure]
1) Press
(CMU) in "SYSTEM>INIT" mode.
A confirmation message appears on the guideline
■
Initializing the communication parameters
SYSTEM
>INIT>CMU
V9.00
MODE ,DATA,RATE,STOP,PARI,TERM,XON,RTS
ONLINE, 8,9600, 1 ,ODD ,CRLF,YES,NO
Initialize OK?
YES
NO
2) Press
(YES) to initialize the parameter.
If not initializing, press
(NO).
Values to be set are as follows.
1. Communication mode = ONLINE
2. Data bit
= 8 bits
3. Baud rate
= 9600bps
4. Stop bit
= 1 bit
5. Parity
= ODD
6. Termination code
=CRLF
7. Flow control
Содержание RCX222
Страница 1: ...RCX222 EUR2153130 E99 Ver 1 30 Userʼs Manual YAMAHA 2 AXIS ROBOT CONTROLLER ...
Страница 2: ......
Страница 14: ......
Страница 43: ......
Страница 46: ......
Страница 50: ...4 MEMO ...
Страница 51: ...Chapter 1 USING THE ROBOT SAFELY Contents 1 Operating environment 1 1 ...
Страница 52: ......
Страница 56: ......
Страница 98: ......
Страница 388: ......
Страница 412: ...5 24 MEMO ...
Страница 414: ......
Страница 430: ......
Страница 442: ......
Страница 450: ...8 8 MEMO ...
Страница 452: ......
Страница 523: ......