12. "SYSTEM" mode
7. TRUE condition / EXPCFG
This parameter selects the operation when the conditional expression, which is used
for the STOPON option in an IF (including ELSEIF), WHILE to WEND, WAIT, MOVE,
or DRIVE statement, is a numeric expression.
This parameter is set to "-1" when the parameters are initialized.
n
NOTE
This parameter is supported by controllers of Ver. 9.08 onwards.
[Procedure]
1) Select "7. TRUE condition" in "SYSTEM>PARAM>OTHERS" mode.
2) Press
(EDIT).
The function key menu changes.
■
Setting "TRUE condition"
SYSTEM
>PARAM>OTHERS
V9.08
−1
not 0
3.Parameter display unit PULSE
4.DO cond. on EMG HOLD
5.Incremental Mode INVALID
6.DI noise filter VALID
7.TRUE condition -1
3) Press
(-1) or
(not 0) to change the setting.
Setting
Meaning
-1 (default setting)
When conditional expression is a numeric expression, the
result is "TRUE" if the expression value is -1, and is "FALSE"
if 0. If the value is other than -1 and 0, an error "6.35:
EXPRESSION ERROR" occurs.
not 0
When conditional expression is a numeric expression, the
result is "TRUE" if the expression value is other than 0, and is
"FALSE" if 0.
4) Press
to quit the edit mode.
Содержание RCX222
Страница 1: ...RCX222 EUR2153130 E99 Ver 1 30 Userʼs Manual YAMAHA 2 AXIS ROBOT CONTROLLER ...
Страница 2: ......
Страница 14: ......
Страница 43: ......
Страница 46: ......
Страница 50: ...4 MEMO ...
Страница 51: ...Chapter 1 USING THE ROBOT SAFELY Contents 1 Operating environment 1 1 ...
Страница 52: ......
Страница 56: ......
Страница 98: ......
Страница 388: ......
Страница 412: ...5 24 MEMO ...
Страница 414: ......
Страница 430: ......
Страница 442: ......
Страница 450: ...8 8 MEMO ...
Страница 452: ......
Страница 523: ......