4-212
4-213
Chapter
4
OPERA
TION
12. "SYSTEM" mode
1. CMU (communication) mode
This parameter sets the communication mode on the computer.
n
NOTE
• Online commands can be executed only in "ONLINE" mode.
• The CMU (communication) mode can be changed with either ONLINE or
OFFLINE statements in robot language.
[Procedure]
1) Select "1. CMU mode" in "SYSTEM>CMU" mode.
2) Press
(EDIT).
The function key menu changes.
■
Setting the "CMU mode"
SYSTEM
>CMU
V9.00
1.CMU mode
ONLINE
2.Data bits
8
3.Baud rate
9600
4.Stop bit
1
5.Parity
ODD
ONLINE
OFFLINE
3) Select the communication mode with
(OFFLINE) or
(ONLINE).
4) Press
to quit the setting. To continue selecting other items, use the cursor (
↑
/
↓
)
keys.