5-16
5-17
Chapter
5
PARALLEL I/O INTERF
ACE
■
Turning the power on (while emergency stop input is off)
DI00
(in SAFETY
connector)
DO00
MPRDY
(in SAFETY
connector)
DO01
DO02
DO03
Approx. 3 sec.
Control power
Emergency stop
ready signal
Emergency stop
contact monitor
Main power ON
ready
Main power
CPU OK
Servo-on state
Alarm
• DO00 (Emergency stop contact monitor) and DO03 (Alarm) turn on after the
control power supply turns on. MPRDY (Main power ON ready) output remains off.
The robot starts with the servo turned off.
n
NOTE
• It takes about 3 seconds until CPU OK is output after turning on the
control power supply
• The main power supply can be left on during operation.
1. Standard I/O interface overview