9-28
9-29
Chapter
9
TROUBLESHOOTING
9.41 : Local variable memory full
Code
: &H0929
Meaning/Cause
: Number of local variables defined within subroutine has
exceeded upper limit.
Action
: 1. Reduce number of local variables defined in the subroutine.
2. Use the global variable.
[10] System setting or hardware errors
10.1 : Robot disconnected
Code
: &H0A01
Meaning/Cause
: Axis control was attempted with "no axis" specified for all axes
of system generation.
Action
: Re-perform the system generation.
10.3 : D.unit disconnected
Code
: &H0A03
Meaning/Cause
: Manual movement was attempted on the axis that is not
specified.
Action
: Do not perform any axis-related operation.
10.6 : DRIVER.unit version mismatch
Code
: &H0A06
Meaning/Cause
: Driver unit version does not match the CPU unit.
Action
: Make sure the CPU unit and driver unit versions match each
other.
10.7 : CPU.unit version mismatch
Code
: &H0A07
Meaning/Cause
: CPU unit version does not match the CPU.
Action
: Make sure the CPU unit and driver unit versions match each
other.
10.8 : Cannot set auxiliary axis
Code
: &H0A08
Meaning/Cause
: Setting of axis that cannot be set as an auxiliary axis was
attempted.
The following axes cannot be set as an auxiliary axis.
• SCARA type robot axes
• X and Y axes except on MULTI type robots
Action
: 1. Do not set an auxiliary axis.
2. Change the axis setting.
[10] System setting or hardware errors
Содержание RCX222
Страница 1: ...RCX222 EUR2153130 E99 Ver 1 30 Userʼs Manual YAMAHA 2 AXIS ROBOT CONTROLLER ...
Страница 2: ......
Страница 14: ......
Страница 43: ......
Страница 46: ......
Страница 50: ...4 MEMO ...
Страница 51: ...Chapter 1 USING THE ROBOT SAFELY Contents 1 Operating environment 1 1 ...
Страница 52: ......
Страница 56: ......
Страница 98: ......
Страница 388: ......
Страница 412: ...5 24 MEMO ...
Страница 414: ......
Страница 430: ......
Страница 442: ......
Страница 450: ...8 8 MEMO ...
Страница 452: ......
Страница 523: ......