4.4 Considering power capacity and generated heat amount
The required power capacity and generated heat amount depend on the robot model and
the number of axes to be controlled.
c
CAUTION
The power supply voltage for the robot controller must always be regulated
within ±10%. If the voltage drops, the robot controller may issue an abnormal
voltage alarm causing the robot to trigger emergency stop. In contrast,
operation at a voltage higher than specified may damage the robot
controller or trigger emergency stop due to detecting an excessive motor
power supply voltage.
Use the following tables as a guide to prepare a power supply and to determine the
control panel size, controller installation method, and cooling means.
■
When connected to 2 axes (Cartesian robot or multi-axis robot)
Axis current sensor value
Power capacity (VA)
Generated heat
amount (W)
X-axis
Y-axis
05
05
500
53
10
05
700
58
20
05
1500
78
10
10
900
63
20
10
1700
83
20
20
2000
90
2400 (HP)
100
* Axis current sensor values can be substituted for each other.
4. Connecting to the power
Содержание RCX222
Страница 1: ...RCX222 EUR2153130 E99 Ver 1 30 Userʼs Manual YAMAHA 2 AXIS ROBOT CONTROLLER ...
Страница 2: ......
Страница 14: ......
Страница 43: ......
Страница 46: ......
Страница 50: ...4 MEMO ...
Страница 51: ...Chapter 1 USING THE ROBOT SAFELY Contents 1 Operating environment 1 1 ...
Страница 52: ......
Страница 56: ......
Страница 98: ......
Страница 388: ......
Страница 412: ...5 24 MEMO ...
Страница 414: ......
Страница 430: ......
Страница 442: ......
Страница 450: ...8 8 MEMO ...
Страница 452: ......
Страница 523: ......