Sensors (cont.) •
Tray 5 Pick
•
Tray 5 Open
•
Tray 5 Lifted
•
Tray 5 Out of Media
initializing
operator abort
press any key to exit
Ink SKU Sen-
sor
This function monitors the state of SKU Sensors and reports any changes
from manual activation on any ink slot. SKU Sensors for each color are dis-
played in a column.
initializing
A B C D
Y 1 0 1 0
C 1 0 1 0
M 1 0 1 0
K 1 0 1 0
operator abort
press any key to exit
Encoders
This function reports readings from each of the continuous Sensors. The
Sensors include:
•
MPT Media Width
•
Y-Axis Position
•
PM Motor Position
•
MP Motor Position
initializing
MPT Media Width: xxxx
Y Axis Position: xxxxxxx
PM Motor Position: x
MP Motor Position: x
operator abort
press any key to exit
Ink Melt Status This function reports the current ink supply status, ink melt heater setpoint,
and temperature, and the Printhead ink level for each color. The colors are
reported as M (magenta), C (cyan). Y (yellow), B (black) corresponding to
the labels in the Ink Loader Chutes.
supply/ph level/setpoint/
new
Y: xx xxxxxx - x.x -xx.x
C: xx xxxxxx - x.x - xx.x
M: xx xxxxxx - x.x - xx.x
B: xx xxxxxx - x.x - xx.x
operator abort
press any key to exit
Table 2 Service Diagnostics Menu Definitions
Menu Item
Description
Control Panel Display
Note
Temperatures
This function reports the current setpoint and temperature values for the indi-
cated Heaters.
Monitor Temp (Setpoint/
now)
LJ:xxx.x-xx.x Y:xxx.x-xx.x
RJ:xxx.x-xx.x C:xxx.x-xx.x
RE:xxx.x-xx.x M:xxx.x-xx.x
DR:xx.x-xx.x B:xxx.x-xx.x
PH:xx.x-xx.x
operator abort
press any key to exit
Abbreviations
used:
LJ = Leftstack
RJ = Right Jet-
stack
RE = Reservoir
DR = Drum
PH = Preheater
IM = Ink Melter
1, 2, 3, or 4
Heaters
This function reports the current enable status of the indicated Heaters as
either off or on, and the power being currently allocated to each Heater
(reported as a percentage of the max rated power for that Heater).
initializing
LJ:Off-000.0 Y:Off-000.0
RJ:Off-000.0 C:Off-000.0
RE:Off-000.0 M:Off-000.0
DR:Off-000.0 B:Off-000.0
PH:Off-000.0
operator abort
press any key to exit
Abbreviations
used:
LJ = Left Jet-
stack
RJ = Right Jet-
stack
RE = Reservoir
DR = Drum
PH = Preheater
IM = Ink Melter
1, 2, 3, or 4
Line Voltage
This function monitors the current average line voltage and reports the cur-
rent value as well as the maximum and minimum values read while the func-
tion during the monitoring period. This also monitors the line voltage seen by
the power supply. AC voltage is sampled at twice the line frequency. Fast line
voltage spikes are not reported. This function helps to evaluate the AC sup-
ply, such as line voltage sags do to the start up of adjacent equipment. You
can run this test overnight to record supply voltage settings.
Pressing any buttons on the Control Panel will terminate the monitoring.
initializing
min: now: max: (volts)
xxx xxx xxx
operator abort
press any key to exit
Tests results are
reported as:
•
Minimum
•
Now
•
Maximum
Front Panel
Buttons
This function monitors the state of the Front Panel buttons and reports any
changes. The function exits if there has been no changes for 10 seconds.
initializing
Auto exit if no input for 10s.
<button> pressed
<button> released
There is no dis-
play result for the
Power Saver but-
ton.
Table 2 Service Diagnostics Menu Definitions
Menu Item
Description
Control Panel Display
Note
Содержание COLORQUBE 8570
Страница 1: ...ColorQube 8570 8870 Printer ColorQube 8570 8870 Service Manual Xerox Internal Use Only...
Страница 2: ......
Страница 152: ...October 2012 3 2 ColorQube 8570 8870 Service Manual Revised 3rd Revision Xerox Internal Use Only Image Quality...
Страница 196: ...October 2012 4 2 ColorQube 8570 8870 Service Manual Revised 3rd Revision Xerox Internal Use Only Repairs and Adjustments...
Страница 304: ...October 2012 5 2 ColorQube 8570 8870 Service Manual Revised 3rd Revision Xerox Internal Use Only Parts List...
Страница 316: ...October 2012 6 2 ColorQube 8570 8870 Service Manual Revised 3rd Revision Xerox Internal Use Only General Troubleshooting...
Страница 372: ...October 2012 7 2 ColorQube 8570 8870 Service Manual Revised 3rd Revision Xerox Internal Use Only Wiring Data...
Страница 392: ...October 2012 8 2 ColorQube 8570 8870 Service Manual Revised 3rd Revision Xerox Internal Use Only Theory of Operation...
Страница 423: ......