![background image](http://html2.mh-extra.com/html/xerox/colorqube-8570/colorqube-8570_service-manual_3756995258.webp)
October 2012
4-64
ColorQube 8570/8870 Service Manual
REP 3.13
Revised, 3rd Revision - Xerox Internal Use Only
Repairs and Adjustments
7.
Open the Exit Module.
8.
Open the Lower Exit Guide Assembly.
9.
Disconnect the Drum Temperature Sensor wiring harness connector
P/J130
.
Figure 3 Disconnecting the Drum Temperature Sensor Wiring Harness Connector
10. Remove the 4 screws (metal, T-20) that secure the Exit Module.
11.
Lift the Exit Module from the chassis.
Figure 4 Removing the Exit Module
Replacement
Seat the Exit Module on the chassis. Torque the 4 screws to 12 in.-lbs and perform Wiper
Blade Alignment procedure (
ADJ 1.1
). The printer may report errors 91,720~91,723, if the
Wiper Assembly is misaligned.
Содержание COLORQUBE 8570
Страница 1: ...ColorQube 8570 8870 Printer ColorQube 8570 8870 Service Manual Xerox Internal Use Only...
Страница 2: ......
Страница 152: ...October 2012 3 2 ColorQube 8570 8870 Service Manual Revised 3rd Revision Xerox Internal Use Only Image Quality...
Страница 196: ...October 2012 4 2 ColorQube 8570 8870 Service Manual Revised 3rd Revision Xerox Internal Use Only Repairs and Adjustments...
Страница 304: ...October 2012 5 2 ColorQube 8570 8870 Service Manual Revised 3rd Revision Xerox Internal Use Only Parts List...
Страница 316: ...October 2012 6 2 ColorQube 8570 8870 Service Manual Revised 3rd Revision Xerox Internal Use Only General Troubleshooting...
Страница 372: ...October 2012 7 2 ColorQube 8570 8870 Service Manual Revised 3rd Revision Xerox Internal Use Only Wiring Data...
Страница 392: ...October 2012 8 2 ColorQube 8570 8870 Service Manual Revised 3rd Revision Xerox Internal Use Only Theory of Operation...
Страница 423: ......