Manual 26247
2301D/2301D-EC Digital Control
Woodward
v
Regulatory Compliance
European Compliance for CE Mark
These listings are limited only to those units bearing the CE Marking.
EMC Directive:
Declared to 89/336/EEC COUNCIL DIRECTIVE of
03 May 1989 on the approximation of the laws of the
member states relating to electromagnetic
compatibility.
Low Voltage Directive:
Declared to the 73/23/EEC COUNCIL DIRECTIVE of
19 February 1973 on the harmonization of the laws
of the Member States relating to electrical
equipment designed for use within certain voltage
limits.
North American Compliance
These listings are limited only to those units bearing the appropriate CSA
identification and marking.
CSA:
CSA Certified for Class I, Division 2, Groups A, B, C,
D, T4 Hazardous Locations and ordinary locations at
70 °C ambient. For use in Canada and the United
States.
Certificate
1150575
NOTE—
Wiring must be in accordance with applicable electric codes with the
authority having jurisdiction.
Marine Compliance
Bureau Veritas:
BV Rules Part C, June 2000
Det Norske Veritas:
Standard for Certification, No. 2.4.2001
Germanischer Lloyd:
Additional Rules and Guidelines, Part 1,
2001
Lloyd’s Register of Shipping:
Type Approval System, Test Specification
Number 1, 2002
Registro Italiano Navale:
RINA Rules 2001 – Part C
NOTE—
Marine certifications apply to specific models only.
Connector J1 must not be used in hazardous locations.
The control must be installed in a suitable enclosure. The final combination must
be approved by the local authority having jurisdiction.
Connect the ground terminal to earth ground.
EXPLOSION HAZARD—Do not remove covers or connect/disconnect
electrical connectors unless power has been switched off or the area
is known to be non-hazardous.
Substitution of components may impair suitability for Class I,
Division 2.
RISQUE D’EXPLOSION—Ne pas enlever les couvercles, ni
raccorder / débrancher les prises électriques, sans vous en
assurez auparavant que le système a bien été mis hors tension;
ou que vous vous situez bien dans une zone non explosive.
La substitution de composants peut rendre ce matériel
inacceptable pour les emplacements de Classe I, Division 2.
Содержание 2301D
Страница 12: ...2301D 2301D EC Digital Control Manual 26247 4 Woodward Figure 1 1a 2301D Outline Drawing Ordinary Locations ...
Страница 13: ...Manual 26247 2301D 2301D EC Digital Control Woodward 5 Figure 1 1b 2301D Outline Drawing Hazardous Locations ...
Страница 14: ...2301D 2301D EC Digital Control Manual 26247 6 Woodward Figure 1 2a 2301D Plant Wiring Diagram sheet 1 ...
Страница 16: ...2301D 2301D EC Digital Control Manual 26247 8 Woodward Figure 1 2c 2301D Plant Wiring Diagram notes ...
Страница 51: ...Manual 26247 2301D 2301D EC Digital Control Woodward 43 Figure 3 4 Typical Transient Response Curves ...
Страница 127: ...Manual 26247 2301D 2301D EC Digital Control Woodward 119 ...
Страница 129: ...Declarations ...