Brine Fogging System Type SOLFOG V3
Index: 02
Change date: 19/09/2023
OI No.: BA DW 042-02 Solfog V3 CB36 EN.docx
Page 29 of 65
NOTICE
The fog maker container must be empty in order to proceed to the next step in the Disinfec-
tion menu using the Enter key. Removing and inserting the fog maker container requires some
effort! Loud snapping sounds are normal.
WARNING!
Danger of irritation or and allergic reactions!
Disinfectants may cause irritation and allergic reactions!
Do not drink!
Keep out of the reach of children!
Do not allow to come into contact with skin or eyes!
Wear chemical-resistant protective gloves and goggles!
Block access to the application room/cabin during disinfection!
Collect the escaping disinfection solution in a plastic container or channel it
directly into the drain. Pay attention to the nationally applicable regulations
for environmental and drinking water protection!
Fig. 21: Menu: Rinse fog maker container
3)
Loosen the two cable couplings. Pull the Fog
(Fig. 13, No. 19) forwards out of the bracket and
remove it downwards.
4)
Empty the fog maker container, rinse it with drinking
water and replace the empty fog maker container. Re-
connect the two cables.
5)
Leave the menu with the Enter key
.
Fig. 22: Menu: Fill politainer
6)
Fill the enclosed empty 1 litre brine politainer with 0.5
litres of water
7)
Add the enclosed disinfection tablet SOLDOS (Code no.
19871) and let it dissolve. (Dissolving the disinfection
tablet generates the Hypochlorous acid/hypochlorite
required for disinfection.) …”
Fig. 23: Pull off politainer connection
8)
Remove the brine politainer from the console and un-
screw the original lid from the politainer.
9)
Pull the politainer connection from the suction line’s
Connecting plug