Brine Fogging System Type SOLFOG V3
Index: 02
Change date: 19/09/2023
OI No.: BA DW 042-02 Solfog V3 CB36 EN.docx
Page 21 of 65
Piping with fog lighting and chrome washer (option)
To install the piping, proceed as follows:
1)
Find a suitable location for the fog inlet into the cabin.
2)
Drill a 47 mm hole in the cabin wall.
3)
Install the fog line from the brine fog maker to the cabin using a pipe with a 40 mm
diameter. Maximum line length 4 m. Connect the special bend with the vertical fog
maker pipe and connect it to the SOLFOG’s outlet pipe. Pay attention to the gradient
in the line.
4)
Push the lighting rod into the special bend and connect the cable on the control hous-
ing. The built-in socket and the software programme for the fog lighting are already
installed during production of the SOLFOG.
5)
Install the chrome-plated nozzle washer on the sauna wall.
Fig. 11: Installation plan fog pipe
01
Technical room
02
Cabin
03
Fog inlet from the brine fog maker
04
Chrome-plated nozzle washer
Minimum gradient 1%
02
04
03
01