9.5.3
Fault removal
Fault
Cause / effect
Action
The device cannot be
switched on
Main fuse defective
Main switch defective
Power supply interrupted
Check/renew fuse
Check main switch
Check power supply
Device without function
incorrect setting
Main fuse defective
Control board defective
Power plug unplugged
Operating contact open
Check/reset settings
Renew fuse
Check/renew circuit board
Check power plug
Close operating contact
Peristaltic pump without
function
Fuse defective
Pump motor defective
Renew fuse
Check/renew pump motor
Push button illumination
without function
Fuse defective
Push button incorrectly
connected electrically
Incorrect setting on the
push button illumination
Renew fuse
Check electrical connection
Correct settings in the Config menu
No discernible scent
Fragrance container
empty/dried up
Fuse defective
Fan defective
incorrect fragrance
Check/replenish fragrance oil concentrate
Check/renew fuse
Renew fan
use suitable fragrance
No fog production
Fog maker container empty
Ultrasonic fog maker de-
fective or unplugged
Fan defective
Transformer for ultrasonic
fog maker defective
Diaphragm dirty
Fog maker container over-
filled
Check line for leaks
Renew ultrasonic fog maker; check ultra-
sonic fog maker plug
Check/renew fan
Renew transformer
Clean diaphragm
Correct filling volume
Fog lighting without light
No fog production
Cable not plugged in
Lighting rod defective
Circuit board output defec-
tive
Check the SOLFOG’s fog production (the
light is only illuminated when the fog pro-
duction is running)
Check cable and coupling
Renew the lighting rod
Check outlet/renew circuit board