Brine Fogging System Type SOLFOG V3
Index: 02
Change date: 19/09/2023
OI No.: BA DW 042-02 Solfog V3 CB36 EN.docx
Page 28 of 65
The disinfection must be documented in the disinfection protocol, regardless of how long the
device was in operation during this time!
Disinfection
A disinfection must be carried out during each politainer change, or at least every 28 days!
7.8.2
Disinfection procedure
To carry out a disinfection, proceed as follows:
NOTICE
You can navigate back to the main menu at any time by using the ESC key in the Disinfection
submenu.
NOTICE
The disinfection programme that has been started can only be cancelled by switching it off at
the main switch. After that, the message “Disinfection necessary” is displayed every time the
device is switched on. The display “Disinfection necessary in 0 days” can be hidden with Esc/En-
ter in order to be able to continue operating the system for a short time until the next disinfec-
tion.
Fig. 18: Connection kit for the disinfection
For disinfection, keep the connection
kit (51) with nozzle adapter (52) at
hand.
Fig. 19: Menu: Disinfection
1)
To carry out the disinfection, switch on the system at
the main switch (Fig. 38, No. 03).
Select the
Disinfection
menu using the arrow keys
and confirm with the Enter key
.
Fig. 20: Menu: Start disinfection
2)
Select
Start
using the operating buttons, start with
the Enter key
and follow the programme guide.
51
52