Brine Fogging System Type SOLFOG V3
Index: 02
Change date: 19/09/2023
OI No.: BA DW 042-02 Solfog V3 CB36 EN.docx
Page 25 of 65
ATTENTION!
Faulty operation due to an unsuitable hose!
The peristaltic pump is fitted with a white dosing hose. For dimensions, see Technical
data in Chapter 3.5.
Dosing hoses with other colours are made of different material and may have differ-
ent dimensions.
This may lead to faulty operation!
Fig. 13: Peristaltic pump
31
Transparent pump cover
(not shown)
32
Safety disc
33
Hose bracket with dosing hose
(hose bracket kit)
34
Roller carrier (covered)
35
Pump casing
41
Suction connection
42
Pressure connection
Fig. 14: Insert roller carrier
1)
Remove the clipped-in transparent pump cover (Fig.
13, No. 31) and the safety disc (Fig. 13, No. 32) from the
pump casing (Fig. 13, No. 35).
At initial commissioning, these parts can be found loose
in the enclosed bag.
2)
Pull the hose bracket (Fig. 13, No. 33) out of the guide
in the housing.
3)
Push the roller carrier (Fig. 13, No. 34) onto the shaft.
35
32
34
33
42
41