Brine Fogging System Type SOLFOG V3
Index: 02
Change date: 19/09/2023
OI No.: BA DW 042-02 Solfog V3 CB36 EN.docx
Page 57 of 65
10
Decommissioning / Storage / Disposal
10.1
Decommissioning
WARNING!
Ignition hazard!
Undiluted fragrance oil concentrates may be highly flammable!
Pay attention to the rules for handling flammable liquids!
Avoid ignition sources (e.g., hot surfaces, sparking, open fire or cigarettes)!
WARNING!
Risk of crushing!
Injury to fingers (crushing) possible!
Wear thin gloves when engaged in fault removal!
Pay attention to the following notices when decommissioning the device:
For decommissioning of a maximum of 28 day, deactivate the device at the main switch.
For decommissioning of more than 7 days, the fog maker container must be manually emp-
tied and cleaned.
Clean and dry the fog maker head with a soft cloth (microfibre cloth).
Remove and dispose of the brine politainer.
Remove the brine pump’s roller carriers to avoid any damage to the dosing hose (see Chapter
7.5 on page 24).
Prior to an extended decommissioning, rinse the device with distilled water to prevent en-
crustations. Empty and dry the fog maker container. Empty and clean the fragrance con-
tainer.
10.2
Storage
Pay attention to the following notices when storing the device:
After decommissioning, store the device in a dry location protected from frost!
Pay attention to the notices in Chapter 3.4.6 on page 15!
10.3
Recommissioning
ATTENTION!
Damage due to incorrect commissioning!
Observe the sequence of the commissioning steps!
Pay attention to the information in the commissioning protocol according to
Chapter 11.3 on page 62!
When recommissioning the device, follow the commissioning steps according to Chapter 7 on
page 23 and pay attention to the points in the commissioning protocol according to Chapter 0
on page 62!