Brine Fogging System Type SOLFOG V3
Index: 02
Change date: 19/09/2023
OI No.: BA DW 042-02 Solfog V3 CB36 EN.docx
Page 51 of 65
9.2
Device maintenance
NOTICE
We recommend that you assign a specialist firm to carry out regular maintenance.
In order to ensure the proper function of the SOLFOG V3, pay attention to the following points:
Disinfection and maintenance in accordance with the maintenance protocol in Chapter 11.5
on page 63.
Stocking of the required consumables. Pay attention to shelf life and storage time!
WARNING!
Health hazard due to germ contamination!
Over-aged brine solution can lead to the formation of germs, which can enter the ap-
plication room via the fogging and be inhaled there!
When stocking the necessary consumables, pay attention to shelf life, storage
time and storability!
Check the use-by date before using a new brine solution!
After opening, the brine has a maximum shelf life of 28 days! After that, the
brine must be disposed of with the politainer!
A disinfection must be carried out during each politainer change, or at least
every 28 days!
ATTENTION!
Brine water leaves stains and corrodes metal!
Remove moist sole stains from the device!
Regularly clean the device!