Brine Fogging System Type SOLFOG V3
Index: 02
Change date: 19/09/2023
OI No.: BA DW 042-02 Solfog V3 CB36 EN.docx
Page 55 of 65
9.5.2
Fault indications
The following fault indications can be displayed on the device.
For the removal of fault indications, see the following fault table.
NOTICE
During a fault in the device, the fogging is interrupted.
Fault indication
Cause / effect
Action
Politainer empty
Brine politainer empty
Peristaltic pump does not
work
Level control plug un-
plugged/defective
Renew politainer
Check peristaltic pump
Check level control plug
Filling time has expired
Brine politainer empty
Peristaltic pump does not
work
Level control plug un-
plugged/defective
Renew politainer
Check peristaltic pump
Check level control plug
Button cycle; Operation
mode not selected
Incorrect operation mode set
Use the Enter key to return to the
main menu
Notice:
This setting is only relevant in the
Push button operation mode
wrong time entry
An unrecognisable time was
entered
Enter correct time
Incorrect Password
Incorrect password entry
Enter correct password
Disinfection necessary
Maximum runtime of 28 days
has expired
Carry out disinfection, as de-
scribed in Chapter 7.8 on page 27