Brine Fogging System Type SOLFOG V3
Index: 02
Change date: 19/09/2023
OI No.: BA DW 042-02 Solfog V3 CB36 EN.docx
Page 20 of 65
ATTENTION!
Install the fog line with a gradient (minimum 1%) and without water trap, so that the
condensation water can run back to the fog maker container and does not remain in
the line. This is necessary for reasons of hygiene to avoid the formation of larger
germ concentrations!
Piping without fog lighting system
To install the piping, proceed as follows:
1)
Find a suitable location for the fog inlet into the cabin.
2)
Drill a 40 mm hole in the cabin wall.
3)
Install the fog line from the brine fog maker to the cabin using a pipe with a 40 mm
diameter. Maximum line length 4 m. Pay attention to the gradient in the line.
4)
Install the nozzle washer on the sauna wall.
Fig. 10: Installation plan fog pipe
01
Technical room
02
Cabin
03
Fog inlet from the brine fog maker
04
Nozzle washer
05
Inner cone of piping
01
02
05
04
03