Sentinel V SC and RT Operation Manual
September
2017
EAR-Controlled Technology Subject to Restrictions Contained on the Cover Page.
Page 261
Velocity Data Format
BIT POSITIONS
BYTE
7/S
6
5
4
3
2
1
0
1
VELOCITY ID
LSB 00h
2
MSB 01h
3
DEPTH CELL #1, VELOCITY 1
LSB
4
MSB
5
DEPTH CELL #1, VELOCITY 2
LSB
6
MSB
7
DEPTH CELL #1, VELOCITY 3
LSB
8
MSB
9
DEPTH CELL #1, VELOCITY 4
LSB
10
MSB
11
DEPTH CELL #2, VELOCITY 1
LSB
12
MSB
13
DEPTH CELL #2, VELOCITY 2
LSB
14
MSB
15
DEPTH CELL #2, VELOCITY 3
LSB
16
MSB
17
DEPTH CELL #2, VELOCITY 4
LSB
18
MSB
↓
(SEQUENCE CONTINUES FOR UP TO MAX # CELLS)
↓
1019
DEPTH CELL #MAX, VELOCITY 1
LSB
1020
MSB
1021
DEPTH CELL #MAX, VELOCITY 2
LSB
1022
MSB
1023
DEPTH CELL #MAX, VELOCITY 3
LSB
1024
MSB
1025
DEPTH CELL #MAX, VELOCITY 4
LSB
1026
MSB
See Table 39 for description of fields
Figure 105.
Velocity Data Format
The number of depth cells is set by
ReadyV
or
Plan
. The value will be calculated based on the
Range and Cell size.