September
2017
Sentinel V SC and RT Operation Manual
Page 260
EAR-Controlled Technology Subject to Restrictions Contained on the Cover Page.
Table 38:
Variable Leader Data Format
Hex Digit
Binary
Byte
Field
Description
49-52
25,26
ES / Salinity
Contains the salinity value of the water at the transducer head
(ES-command). This value may be a manual setting or a reading
from a conductivity sensor.
Scaling: LSD = 1 part per thousand; Range = 0 to 40 ppt
53-56
27,28
ET / Temperature Contains the temperature of the water at the transducer head
(ET-command). This value may be a manual setting or a reading
from a temperature sensor.
Scaling: LSD = 0.01 degree; Range = -5.00 to +40.00 degrees
57,58
59,60
61,62
29
30
31
MPT minutes
MPT seconds
MPT hundredths
This field contains the Minimum Pre-Ping Wait Time between
ping groups in the ensemble.
63,64
65,66
67,68
32
33
34
H/Hdg Std Dev
P/Pitch Std Dev
R/Roll Std Dev
These fields contain the standard deviation (accuracy) of the
heading and tilt angles from the gyrocompass/pendulums.
Scaling (Heading): LSD = 1
°
; Range = 0 to 180
°
Scaling (Tilts): LSD
= 0.1
°
; Range = 0.0 to 20.0
°
69-70
71-72
73-74
75-76
77-78
79-80
81-82
83-84
35
36
37
38
39
40
41
42
ADC Channel 0
ADC Channel 1
ADC Channel 2
ADC Channel 3
ADC Channel 4
ADC Channel 5
ADC Channel 6
ADC Channel 7
0
Battery Voltage 0.1volts
0
0
0
0
0
0
85-114
43-57
Reserved
0
115-116
58
RTC Century
These fields contain the time from the Sentinel V’s Y2K compliant
real-time clock (RTC) that the current data ensemble began. The
TT-command (Set Real-Time Clock) initially sets the clock. The
Sentinel V does account for leap years.
117-118
59
RTC Year
119-120
60
RTC Month
121-122
61
RTC Day
123-124
62
RTC Hour
125-126
63
RTC Minute
127-128
64
RTC Seconds
129-130
65
RTC Hundredths
131-132
66
Spare
Spare