PC4 – Display Voltage Monitor ADC Data
The command shows the raw and converted ADC data for the first four channels:
•
ADCH0 = Vin (VBATT)
•
ADCH1 = Iin
•
ADCH2 = Vio
•
ADCH3 = Vcore
>pc4
Battery ADC data is sampled and displayed in a loop.
Press any key to exit the loop.
Count Chan0 Chan1 Chan2 Chan3 Vin(cV) Iin(cA) Vio(cV) Vcore(cV)
\ 93 c088 0d60 9644 fc74 1709.188 6.896 342.340 183.410
>
PC40 – Display Scrolling Voltage Monitor ADC Data
PC40 is the same as PC4 except the data is displayed in a repeating loop at approximately 0.5-sec update
rate.
>pc40
Battery ADC data is sampled and displayed in a loop.
Press any key to exit the loop.
Count Chan0 Chan1 Chan2 Chan3 Vin(cV) Iin(cA) Vio(cV) Vcore(cV)
0 c088 0d60 98a6 f54e 1709.188 6.896 342.438 183.227
0 c088 0d60 98a6 fc74 1709.188 6.896 342.438 183.410
0 c088 0d60 9644 fc74 1709.188 6.896 342.340 183.410
0 c088 089c 9644 0ac0 1709.188 6.774 342.340 183.776
0 c088 0d60 98a6 f2ec 1709.188 6.896 342.438 183.166
0 c088 089c 98a6 11e6 1709.188 6.774 342.438 183.959
0 c088 122e 98a6 f7b0 1709.188 7.019 342.438 183.288
0 be26 0d60 98a6 fa12 1708.517 6.896 342.438 183.349
>