Fault Log Commands
The Sentinel V Real-Time ADCP uses the following commands to aid in troubleshooting and testing.
Available Fault Log Commands
This section lists the most often used Fault Log commands.
>f?
Available Commands:
FC ----------------------- Clear Fault Log
FD ----------------------- Display Fault Log
F? ----------------------- Display Fault Log Commands
>
Fault Log Command Descriptions
FC – Clear Fault Log
Purpose
Clears the fault log.
Format
FC
Recommended Setting. Use as needed.
Description Use this command to clear the fault log of all previous entries.
FD – Display Fault Log
Purpose
Displays the fault log.
Format
FD
Recommended Setting. Use as needed.
Description Displaying the fault log will list why a built-in test failed. This may aid in troubleshooting.
Example
>FD
Total Unique Faults = 2
Overflow Count = 0
Time of first fault: 97/11/05,11:01:57.70
Time of last fault: 97/11/05,11:01:57.70
Fault Log:
Entry # 0 Code=0a08h Count= 1 Delta= 0 Time=97/11/05,11:01:57.70
Parameter = 00000000h
Tilt axis X over range.
Entry # 1 Code=0a16h Count= 1 Delta= 0 Time=97/11/05,11:01:57.70
Parameter = 00000000h
Tilt Y axis ADC under range.
End of fault log.