Connect only items that have been specified as part of the
VICTUS™ Femtosecond Laser Platform ME system or specified as being com‐
patible with the VICTUS™ Femtosecond Laser Platform ME system!
The following items form the VICTUS™ Femtosecond Laser Platform ME
system:
– VICTUS™ Femtosecond Laser Platform
– Patient bed with swivel position 16,5°, 60° or 70°
– Uninterruptible power supply (UPS): see relevant customer configura‐
tion sheet (transient currents up to 16 A possible)
The following parts of the VICTUS™ Femtosecond Laser Platform ME system are
suitable for use within the patient environment:
n
VICTUS™ Femtosecond Laser Platform
n
Patient bed with swivel position 16,5°, 60° or 70°
1.3
Use with other medical devices
Do not use VICTUS™ Femtosecond Laser Platform together with medical
devices other than the devices described in this section.
Patient beds "LS Comfort" and "Patient Support System S60" by AKRUS
GmbH & Co KG
These patient beds are medical devices that are approved in accordance with the
Medical Device Directive. Technolas Perfect Vision GmbH has assessed their use in
combination with VICTUS™ Femtosecond Laser Platform. Technolas Perfect Vision
GmbH allows only specific versions of the "LS Comfort" or the "Patient Support
System S60" patient bed to be used with VICTUS™ Femtosecond Laser Platform. It
must be installed by an Authorized Service Technician. For information about
how to operate the patient bed refer to the user manual "Laser Patient Bed LS
Comfort" or "Patient Support System PSS S60" by AKRUS GmbH & Co KG. Refer to
Ä
Chapter 4.1.1 ‘Interface of the patient beds "LS Comfort" and "Patient Support
System S60" by AKRUS GmbH & Co KG’ on page 4 - 2
for the interface description.
1.4
List of abbreviations
ACD
Anterior Chamber Depth
AI
Arcuate Incisions
BSS
Balanced Salt Solution
CXL
Crosslinking
D
Diopter
EHD
Exit Height Difference
EMC
Electromagnetic Compatibility
ME system
L
WARNING
L
WARNING
INTRODUCTION
1
SKU: 70005780TPV * Version 6 * UM-100010770 GB
1 - 2
TPV Controlled Document / Status: Effective / Effective Date: Jun 14, 2017 2:38:46 PM
UM-100010770 / Version 6 / Page 14 of 207
Содержание Victus
Страница 1: ...User Manual VICTUS Femtosecond Laser Platform SW V3 3 SP02 UM 100010770 GB SKU 70005780TPV Version 6 ...
Страница 12: ...GENERAL INFORMATION A SKU 70005780TPV Version 6 UM 100010770 GB A 4 ...
Страница 16: ...INTRODUCTION 1 SKU 70005780TPV Version 6 UM 100010770 GB 1 4 ...
Страница 48: ...CLINICAL APPLICATIONS 5 SKU 70005780TPV Version 6 UM 100010770 GB 5 6 ...
Страница 186: ...TREATMENT 9 SKU 70005780TPV Version 6 UM 100010770 GB 9 60 ...
Страница 201: ...Appendix 13 SKU 70005780TPV Version 6 UM 100010770 GB 13 1 ...
Страница 202: ...Table of contents A EMC declaration APPENDIX 13 SKU 70005780TPV Version 6 UM 100010770 GB 13 2 ...