2-4
Sun StorEdge 6320 System 1.0 Reference and Service Manual • April 2003
2.1.5
Fibre Channel Switches
The Sun StorEdge network 2 Gbit Fibre Channel switch-16 switch provides cable
consolidation and increased connectivity. The Sun StorEdge network FC switch-16
switches are used for the internal data interconnection infrastructure.
The switches are paired to provide data path redundancy. Two switches are used in
each Sun StorEdge 6320 system.
These switches can be monitored through the SANbox2 Manager GUI.
These switches are configured using the Sun StorEdge Configuration Service
software, which is installed on the customer’s host. These are discussed in “Sun
StorEdge Configuration Service Software” on page 2-6 and “Sun StorEdge
Configuration Service Software” on page 5-1.
The Sun StorEdge 6320 switchless system will not have switches present.
2.1.6
Storage Service Processor Accessory Tray
The Storage Service Processor accessory tray is an enclosure that contains all the
components necessary to support the Sun StorEdge Remote Response software. This
enclosure simplifies serviceability, as the entire unit is a FRU.
The Storage Service Processor accessory tray contains the following:
■
Serial Network Terminal Concentrator (NTC) used for remote serviceability
support
■
Ethernet router/firewall used to provide additional security to Sun from the
customer management LAN
■
Personal Computer Memory Card International Association (PCMCIA)
compatible modem
■
A single AC power supply used by all components in the tray
2.1.7
Sun StorEdge Expansion Cabinet
The Sun StorEdge 6320 system is packaged in the Sun StorEdge Expansion Cabinet,
which is also used for several other Sun products. The customer-accessible areas of
the system are clearly labeled. Service-accessible areas of the system are clearly
labeled as such. All physical configurations will be completed by Sun-trained
personnel. Customers not trained for service by Sun will have significantly limited
access to the physical layout of the system.
Содержание StorEdge 6320 System 1.0
Страница 10: ...x Sun StorEdge 6320 System 1 0 Reference and Service Manual May 2003 A 8 Miscellaneous Cable Requirements A 10...
Страница 12: ...xii Sun StorEdge 6320 System 1 0 Reference and Service Manual May 2003...
Страница 16: ...xvi Sun StorEdge 6320 System 1 0 Reference and Service Manual May 2003...
Страница 44: ...1 12 Sun StorEdge 6320 System 1 0 Reference and Service Manual May 2003...
Страница 54: ...2 10 Sun StorEdge 6320 System 1 0 Reference and Service Manual April 2003...
Страница 66: ...3 12 Sun StorEdge 6320 System 1 0 Reference and Service Manual May 2003...
Страница 110: ...6 6 Sun StorEdge 6320 System 1 0 Reference and Service Manual May 2003...
Страница 124: ...8 10 Sun StorEdge 6320 System 1 0 Reference and Service Manual May 2003...
Страница 142: ...11 4 Sun StorEdge 6320 System 1 0 Reference and Service Manual May 2003...
Страница 158: ...12 16 Sun StorEdge 6320 System 1 0 Reference and Service Manual May 2003...
Страница 172: ...Glossary 4 Sun StorEdge 6320 System 1 0 Reference and Service Manual May 2003...