1-6
Sun StorEdge 6320 System 1.0 Reference and Service Manual • May 2003
1.3
System-Level Support Information
shows Sun StorEdge 6320 system information.
1.4
Sun StorEdge 6320 System Features
The following are features available on the Sun StorEdge 6320 system:
■
Installation
– The Sun StorEdge 6320 system requires minimal setup. The Sun
StorEdge 6020 array units are preconfigured at the factory, eliminating the need to
create storage pools. You can create volumes as required within allowed limits.
■
RAID Striped Data with Standby Hot Spare
– Internal Sun StorEdge 6020 arrays
are preconfigured with RAID 5 storage pools at the factory. Each Sun StorEdge
6020 array is preconfigured in the factory with one RAID5 storage pool and one
hot spare. The hot spare is located in slot 14. You can change to RAID 1 or RAID
0.
■
Volume Access Control
– The Sun StorEdge 6320 systems provides support for
volume access control. Support for initiator groups and volume groups are
provided. The Sun StorEdge 6020 arrays support a maximum of 64 volumes per
storage array and provide support for initiator groups. The Sun StorEdge 6020
can be used to set volume access control properties for a group of host initiators.
■
Bandwidth
– The system uses Fibre Channel technology to provide the optimum
bandwidth. The integrated front-end switches are 2 Gbit/second transfers that
provide for 2 Gbit host connectivity.
TABLE 1-1
Sun StorEdge 6320 System-Level Configurations
System
Bandwidth
1
Capacity
2
Maximum Host
Connectivity
3
Maximum LUNs
LUN
Masking
Sun StorEdge 6320
and 6320 switchless
systems
4400
Mbytes/sec
maximum
504 Gbytes to 45
Tbytes
5 (with integrated
switches)
88 (with external
switches)
704 (64 per Sun
StorEdge 6020
array)
Yes
1 - Bandwidth is defined as the theoretical maximum using full-duplex Fibre Channel connections.
2 - Minimum capacity is calculated using 36 Gbyte drives and maximum capacity is calculated using 146.8 Gbyte drives. The available
data capacity using default configurations are slightly lower due to capacity used for parity and hot spares.The minimum size is 10
Mbyte for all LUNs. The maximum size is 2 Tbyte for all LUNs.
3 - All host connections are redundant partner groups.
Содержание StorEdge 6320 System 1.0
Страница 10: ...x Sun StorEdge 6320 System 1 0 Reference and Service Manual May 2003 A 8 Miscellaneous Cable Requirements A 10...
Страница 12: ...xii Sun StorEdge 6320 System 1 0 Reference and Service Manual May 2003...
Страница 16: ...xvi Sun StorEdge 6320 System 1 0 Reference and Service Manual May 2003...
Страница 44: ...1 12 Sun StorEdge 6320 System 1 0 Reference and Service Manual May 2003...
Страница 54: ...2 10 Sun StorEdge 6320 System 1 0 Reference and Service Manual April 2003...
Страница 66: ...3 12 Sun StorEdge 6320 System 1 0 Reference and Service Manual May 2003...
Страница 110: ...6 6 Sun StorEdge 6320 System 1 0 Reference and Service Manual May 2003...
Страница 124: ...8 10 Sun StorEdge 6320 System 1 0 Reference and Service Manual May 2003...
Страница 142: ...11 4 Sun StorEdge 6320 System 1 0 Reference and Service Manual May 2003...
Страница 158: ...12 16 Sun StorEdge 6320 System 1 0 Reference and Service Manual May 2003...
Страница 172: ...Glossary 4 Sun StorEdge 6320 System 1 0 Reference and Service Manual May 2003...