Chapter 1
Introduction
1-11
Reliability
• Mechanical for easier insertion and extraction and better locking mechanisms for
disks and other FRUs
• Blind mate connectors to avoid bent pins on FRU insertion
Availability
• Enhanced temperature monitoring to shut down the system only when temperature
thresholds are exceeded
• Automated power cooling unit (PCU) adjusts fan speed based on the temperature
monitoring
• Improved battery recharge control to avoid missing battery recharge if a Sun StorEdge
6020 array was shut down during battery recharge cycles
• Automated and online firmware upgrade and downgrades
• Hardware integrated device electronics (IDE) interface to introduce cache saving
procedures without adding battery cost as higher density enclosures are developed
Fault detection,
fault isolation, and
failure fencing
• Support for parity on RISC RAM hardware
• Loop card with standard SSC100 management processor and VSC055 serial backplane
controller provides better enclosure management
• Faster and modular loop card serial communication protocol
• Failure fencing (fault containment) in case of hardware failures
• Automatic hardware bypass of the faulty drive should a drive cause loop disruptions
• Hardware support that creates a diagnostics loop of disks for performing background
tests
• Temperature sensors for continuous threshold based temperature monitoring. The
temperature sensors are located close to heat spots to provide accurate temperature
measurements
• Fibre Channel ECHO ELS support, which allows for both external echo tests (invoked
from the Sun StorEdge 6020 array) and passive echo tests (invoked from the Fibre
Channel switch)
• External and internal loopback test support to test front-end controller and back-end
Fibre Channel ports
• Fibre Channel link status counters for threshold-based analysis of link error statistics
TABLE 1-2
RAS Features (Continued)
Benefits
RAS Features
Содержание StorEdge 6320 System 1.0
Страница 10: ...x Sun StorEdge 6320 System 1 0 Reference and Service Manual May 2003 A 8 Miscellaneous Cable Requirements A 10...
Страница 12: ...xii Sun StorEdge 6320 System 1 0 Reference and Service Manual May 2003...
Страница 16: ...xvi Sun StorEdge 6320 System 1 0 Reference and Service Manual May 2003...
Страница 44: ...1 12 Sun StorEdge 6320 System 1 0 Reference and Service Manual May 2003...
Страница 54: ...2 10 Sun StorEdge 6320 System 1 0 Reference and Service Manual April 2003...
Страница 66: ...3 12 Sun StorEdge 6320 System 1 0 Reference and Service Manual May 2003...
Страница 110: ...6 6 Sun StorEdge 6320 System 1 0 Reference and Service Manual May 2003...
Страница 124: ...8 10 Sun StorEdge 6320 System 1 0 Reference and Service Manual May 2003...
Страница 142: ...11 4 Sun StorEdge 6320 System 1 0 Reference and Service Manual May 2003...
Страница 158: ...12 16 Sun StorEdge 6320 System 1 0 Reference and Service Manual May 2003...
Страница 172: ...Glossary 4 Sun StorEdge 6320 System 1 0 Reference and Service Manual May 2003...