RM0453 Rev 2
871/1454
RM0453
General-purpose timer (TIM2)
893
Bits 11:8
ETF[3:0]
: External trigger filter
This bit-field then defines the frequency used to sample ETRP signal and the length of the
digital filter applied to ETRP. The digital filter is made of an event counter in which N
consecutive events are needed to validate a transition on the output:
0000: No filter, sampling is done at f
DTS
0001: f
SAMPLING
=f
CK_INT
, N=2
0010: f
SAMPLING
=f
CK_INT
, N=4
0011: f
SAMPLING
=f
CK_INT
, N=8
0100: f
SAMPLING
=f
DTS
/2, N=6
0101: f
SAMPLING
=f
DTS
/2, N=8
0110: f
SAMPLING
=f
DTS
/4, N=6
0111: f
SAMPLING
=f
DTS
/4, N=8
1000: f
SAMPLING
=f
DTS
/8, N=6
1001: f
SAMPLING
=f
DTS
/8, N=8
1010: f
SAMPLING
=f
DTS
/16, N=5
1011: f
SAMPLING
=f
DTS
/16, N=6
1100: f
SAMPLING
=f
DTS
/16, N=8
1101: f
SAMPLING
=f
DTS
/32, N=5
1110: f
SAMPLING
=f
DTS
/32, N=6
1111: f
SAMPLING
=f
DTS
/32, N=8
Bit 7
MSM
:
Master/Slave mode
0: No action
1: The effect of an event on the trigger input (TRGI) is delayed to allow a perfect
synchronization between the current timer and its slaves (through TRGO). It is useful if we
want to synchronize several timers on a single external event.