RM0453 Rev 2
567/1454
RM0453
Analog-to-digital converter (ADC)
591
the correct operation of the ADC, the VBAT pin is internally connected to a bridge divider.
This bridge is automatically enabled when VBATEN is set, to connect V
BAT
to the ADC
V
IN
[14] input channel. As a consequence, the converted digital value is half the V
BAT
voltage. To prevent any unwanted consumption on the battery, it is recommended to enable
the bridge divider only when needed for ADC conversion.
Figure 85. V
BAT
channel block diagram
18.11 ADC
interrupts
An interrupt can be generated by any of the following events:
•
End Of Calibration (EOCAL flag)
•
ADC power-up, when the ADC is ready (ADRDY flag)
•
End of any conversion (EOC flag)
•
End of a sequence of conversions (EOS flag)
•
When an analog watchdog detection occurs (AWD1, AWD2, AWD3 flags)
•
When the Channel configuration is ready (CCRDY flag)
•
When the end of sampling phase occurs (EOSMP flag)
•
when a data overrun occurs (OVR flag)
Separate interrupt enable bits are available for flexibility.
MSv45367V2
VBATEN control bit
Address
/data
b
us
ADC V
IN
[14]
ADC
+
-
V
BAT
V
BAT
/3
Table 109. ADC interrupts
Interrupt event
Event flag
Enable control bit
End Of Calibration
EOCAL
EOCALIE
ADC ready
ADRDY
ADRDYIE
End of conversion
EOC
EOCIE
End of sequence of conversions
EOS
EOSIE
Analog watchdog 1 status bit is set
AWD1
AWD1IE