Appendix D. OCP Information
92
D0
ROM error.
ROM checksum incorrect.
Retry operation.
After several occurrences, contact
Technical Support.
D1
RAM error.
Initialization failed.
D2
NVRAM error.
R/W operation to NVRAM has failed.
D3
CTC Error.
Timer unit failed during initialization.
D4
UART Error.
Frame overrun or parity error on serial
interface.
D5
Display Error.
Communication to display failed.
Retry operation.
After several occurrences, contact
Technical Support.
D6
Memory Error, Stack and heap overflow.
D7
Fatal system error.
D8
Database error.
D9
No SCSI ID detected.
DA
In Library Health Check diagnostic, the bar
code reader has read different bar code data
for the same cartridge label.
Check the bar code label on a scratch
cartridge and run the diagnostic
again. If the error recurs, contact
Technical Support.
DB
External drive sled cooling fan error
(fan motion has stopped).
Sub-code indicates the affected fan:
00 = Drive Sled 1
01 = Drive Sled 2
Check if the indicated fan is
operational and not obstructed.
If the error persists, contact Technical
Support.
F0
Drive Over-Temperature Condition.
Check ambient temperature
conditions and check all fans, after
several occurrences, contact
Technical Support.
F1
Drive Communication Error.
Library controller lost communication to
drive.
Retry operation; if not successful,
contact Technical Support.
F2
Drive sled not present.
Error Code
Description
User Action