Appendix D. OCP Information
88
Error Codes
If an error occurs during operation of the library, the library stops the current
operation and displays an error code on the OCP. Try to resolve the error as noted in
the error code tables starting on page 89. If the error persists, contact SpectraGuard
Technical Support.
Example Error Code
Following is one example of an OCP error code:
EVENT -6
89 04
Where:
• Sequence number
–6
indicates the position in sequence list (
0
is the most
recent).
• Error Code
89
indicates that the gripper is blocked.
• Sub-Code
04
indicates that it was an error during gripper close.
Time Stamps
The library event log includes a date stamp for each event. Press ENTER to display the
associated timestamp in the following format:
ddd:hh:mm:ss:HH
Where:
• ddd: days
• hh: hours
• mm: minutes
• ss: seconds
• HH: 1/100 second
Note: