Appendix
A.1 Tags of the technology object SpeedAxis
S7-1500 Motion Control V13 Update 3
326
Function Manual, 07/2014, A5E03879256-AC
A.1.10
StatusWord tag (speed axis)
The <TO>.StatusWord tag contains the status information of the technology object.
Notes on the evaluation of the individual bits (e.g. bit 0, "Enable") can be found in the
Evaluating StatusWord, ErrorWord and WarningWord (Page 175) section.
Tag
Tag
Data type
Values
W
Description
Status
tus-
Word
DWORD
-
RON
Status data of the technology object
Bit 0
-
-
-
"Enable"
Enable status
0: Technology object disabled
1: Technology object enabled
Bit 1
-
-
-
"Error"
0: No error present
1: Error present
Bit 2
-
-
-
"RestartActive"
0: No "Restart" active
1: "Restart" active. The technology object is being reinitialized.
Bit 3
-
-
-
"OnlineStartValuesChanged"
0: "Restart" tag unchanged
1: Change to "Restart" tag. For the changes to be applied, the
technology object must be reinitialized.
Bit 4
-
-
-
"ControlPanelActive"
Axis control panel
0: disabled
1: enabled
Bit 5
-
-
-
Reserved
Bit 6
-
-
-
"Done"
0: Motion job in process, or axis control panel enabled
1: No motion job in process and axis control panel disabled
Bit 7
-
-
-
Reserved
Bit 8
-
-
-
Reserved
Bit 9
-
-
-
"JogCommand"
0: No "MC_MoveJog" frame active
1: "MC_MoveJog" job active
Bit 10 -
-
-
"VelocityCommand"
0: No "MC_MoveVelocity" job active
1: "MC_MoveVelocity" job active
Bit 11 -
-
-
Reserved