Configuring
6.8 Parameter view
S7-1500 Motion Control V13 Update 3
170
Function Manual, 07/2014, A5E03879256-AC
Bad modify values
●
Modify values with process-related errors can be transmitted.
●
Modify values with syntax errors cannot be transmitted.
6.8.4.9
Comparing values
You can use comparison functions to compare the following memory values of a parameter:
●
Start value project
●
Start value PLC
Requirements
●
There is an online connection.
●
The technology object is downloaded to the CPU.
●
The Parameter view of the technology object is open.
Procedure
To compare the start values on the various target systems, follow these steps:
1.
Click the "Selection of compare values" icon
.
A selection list containing the comparison options opens:
–
Start value project - Start value PLC (default setting)
2.
Select the desired comparison option.
The selected comparison option is executed as follows:
–
A scales symbol appears in the header cells of the two columns selected for
comparison.
–
Symbols are used in the "Compare result" column to indicate the result of the
comparison of the selected columns.