Appendix
A.4 Technology alarms
S7-1500 Motion Control V13 Update 3
368
Function Manual, 07/2014, A5E03879256-AC
A.4
Technology alarms
A.4.1
Overview
The following table shows an overview of the technology alarms and the corresponding
alarm reactions. When a technology alarm occurs, evaluate the entire indicated alarm text, in
order to find the precise cause.
Legend
No.
Number of the technology alarm
(corresponds to <TO>.ErrorDetail.Number)
Response
Effective alarm reaction
(corresponds to <TO>.ErrorDetail.Reaction)
Error bit
Bit that is set in <TO>.ErrorWord when the technology alarm occurs
Warning bit
Bit that is set in <TO>.WarningWord when the technology alarm occurs
Restart
To acknowledge the technology alarm, the technology object must be reinitialized
(restart).
Alarm text
Indicated alarm test (limited)
List of the technology alarms
No.
Response
Error bit
Warning bit
Restart
Alarm text
101 Remove enable
X1 (Configuration-
Fault)
-
X
Error in the configuration.
104 Stop with maximum
dynamic values
X1 (Configuration-
Fault)
-
-
Error in the specification of software limit
switches.
105 Remove enable
X1 (Configuration-
Fault)
-
X
Configuration mode (drive/actuator).
106 Remove enable
X1 (Configuration-
Fault)
-
X
Configuration error in the drive actuator
driver.
107 Remove enable
X1 (Configuration-
Fault)
-
X
Configuration error encoder.
108 Remove enable
X1 (Configuration-
Fault)
-
X
Configuration error encoder driver.
109 Remove enable
X1 (Configuration-
Fault)
-
-
Configuration error.
110 No reaction
-
X1
(Configuration-
Fault)
-
Configuration is being internally adapted.
201 Remove enable
X0 (SystemFault) -
-
Internal error.
202 No reaction
X0 (SystemFault) -
-
Internal configuration error.
203 Remove enable
X0 (SystemFault) -
-
Internal error. Please contact customer
service.