Instructions
11.1 S7-1500 Motion Control V2
S7-1500 Motion Control V13 Update 3
266
Function Manual, 07/2014, A5E03879256-AC
Applies to
●
Synchronous axis
●
Positioning axis
Requirements
●
The technology object has been configured correctly.
●
The technology object is enabled.
Override response
The "MC_MoveSuperimposed" job is aborted by:
●
Disabling the axis with "MC_Power.Enable" = FALSE
●
"MC_Home" job "Mode" = 3, 5
●
"MC_Halt" job
●
"MC_MoveAbsolute" job
●
"MC_MoveRelative" job
●
"MC_MoveVelocity" job
●
"MC_MoveJog" job
●
"MC_GearIn" job
●
"MC_MoveSuperimposed" job
Starting a "MC_MoveSuperimposed" job aborts an active "MC_MoveSuperimposed" job.