Diagnostics
10.6 Positioning axis/synchronous axis technology object
S7-1500 Motion Control V13 Update 3
Function Manual, 07/2014, A5E03879256-AC
229
Additional information
An option for the evaluation of the individual status bits can be found in the Evaluating
StatusWord, ErrorWord and WarningWord (Page 175) section.
10.6.2
Motion status
Description
You use the "Technology object > Diagnostics > Motion status" diagnostic function in the TIA
Portal to monitor the motion status of the axis. The Diagnostics function is available in online
operation.
"Current values" area
The following table shows the meaning of the status data:
Status
Description
Target position
Current target position of an active positioning job
The target position value is only valid while a positioning job is busy.
(<TO>.StatusPositioning.TargetPosition)
Actual position
Actual position of the axis
If the technology object is not homed, then the value is displayed relative to the position that
existed when the technology object was enabled.
(<TO>.ActualPosition)
Actual velocity
Actual velocity of the axis
(<TO>.ActualVelocity)
Velocity override
Percentage correction of the velocity override
The velocity setpoint specified in motion control instructions or set by the axis control panel are
superimposed with an override signal and corrected as a percentage. Valid velocity correction
values range from 0.0 % to 200.0 %.
(<TO>.Override.Velocity)
"Dynamic limits" area
This area displays the limit values for the dynamic parameters.
The following table shows the meaning of the status data:
Status
Description
Velocity
Configured maximum velocity
(<TO>.DynamicLimits.MaxVelocity)
Acceleration
Configured maximum acceleration
(<TO>.DynamicLimits.MaxAcceleration)
Deceleration
Configured maximum deceleration
(<TO>.DynamicLimits.MaxDeceleration)