Examination
Digital Radiography
24
/ 52
AXD3-340.620.13.01.02
Operator Manual
Selecting the dominants
The dominants are filed in the organ programs or can be set on the integrated
generator control console.
Multiple selection of the dominants is possible.
Exception: central circular dominant.
◆
Press one of the keys:
Left dominant
Middle dominant
Right dominant
Central circular dominant
When collimating under fluoroscopy, take care that the selected left or right dom-
inant lies completely in the radiation field.
Otherwise there will be overexposure because of the inappropriate acquisition of
the measured exposure values.
The position of the measuring field/of the measuring field in relation to the object
can be checked on the LIH image by means of brief fluoroscopy. A diagram with
the position and size of the relevant measuring field is displayed briefly on the
monitor.
Warning
Please make sure when changing the selection of the dominants that the cor-
rect dominant is always selected.
If a selected left and/or right dominant becomes invalid temporarily, e.g. due to
collimation, then the central circular dominant is selected and displayed automat-
ically.
The originally selected dominant(s) will be active and displayed again when the
collimator is opened again.
Содержание AXIOM Iconos R200
Страница 2: ......
Страница 12: ...System Overview Table of Contents 4 44 AXD3 340 620 13 01 02 Operator Manual ...
Страница 18: ...System Overview System Description 10 44 AXD3 340 620 13 01 02 Operator Manual ...
Страница 32: ...System Overview Protective Measures 24 44 AXD3 340 620 13 01 02 Operator Manual ...
Страница 52: ...System Overview Operating and Display Elements 44 44 AXD3 340 620 13 01 02 Operator Manual ...
Страница 56: ...System Operation Table of Contents 4 32 AXD3 340 620 13 01 02 Operator Manual ...
Страница 78: ...System Operation System Settings 26 32 AXD3 340 620 13 01 02 Operator Manual ...
Страница 84: ...System Operation Setting the Image Geometry 32 32 AXD3 340 620 13 01 02 Operator Manual ...
Страница 90: ...Examination Transferring and Positioning the Patient 6 52 AXD3 340 620 13 01 02 Operator Manual ...
Страница 132: ...Examination Digital Radiography 48 52 AXD3 340 620 13 01 02 Operator Manual ...
Страница 172: ...POLYDOROS SX 65 80 Integrated Control Console 36 36 AXD3 340 620 13 01 02 Operator Manual ...
Страница 184: ...Accessories Standard Accessories 12 54 AXD3 340 620 13 01 02 Operator Manual ...
Страница 228: ...Technical Description Table of Contents Operator Manual 2 of 12 AXD3 340 620 13 01 02 ...