CALCulate Subsystem FSE
1065.6016.12
6.32
E-16
:CALCulate<1|2>:LIMit<1 to 8>:SPECtrum:SWITching?
This command queries the total result of the spectrum due to switching transients measurements for
list mode. For frequency mode, the limit violations are queried with command
CALCulate:LIMit:FAIL?
Parameter:
The result is displayed in character data form. Possible values are:
PASSED
limit not exceeded
FAILED
limit exceeded
ABORTED
measurement aborted
RUNNING
measurement not completed
Examples:
":CALC:LIM:SPEC:SWIT?"
Result:
PASSED
Features:
*RST value:
--
SCPI:
device-specific
Modes:
BTS, MS
This command is a query and therefore not assigned a *RST value. The numeric suffixes <1|2> or
<1 to 8> are not significant for this command.
:CALCulate<1|2>:LIMit<1 to 8>:SPECtrum:SWITching:FAILs?
This command queries the number of limit violations of the spectrum due to switching transient
measurement for list mode.The number of limit violations is the total of all violations above and below
the carrier. For frequency mode, the limit violations are queried with command
CALCulate:LIMit:FAIL?.
Examples:
":CALC:LIM:SPEC:SWIT:FAIL?"
Features:
*RST value:
--
SCPI:
device-specific
Modes:
BTS, MS
This command is a query and therefore not assigned a *RST value. The numeric suffixes <1|2> or
<1 to 8> are not significant for this command.
:CALCulate<1|2>:LIMit<1 to 8>:SPURious? TXBand | OTXBand | RXBand | IDLeband
This command queries the total result of the spurious emissions measurement.
Parameter:
The result is displayed in character data form. Possible values are:
PASSED
limit not exceeded
FAILED
limit exceeded
ABORTED
measurement aborted
RUNNING
measurement not completed
Examples:
":CALC:LIM:SPUR? OTXB"
Result:PASSED
Features:
*RST value:
--
SCPI:
device-specific
Modes:
BTS, MS
TXBand
TX-band
OTXBand
Not TX-band
RXBand
RX-band (option FSE-K11 only)
IDLeband
IDLeband (option FSE-K10 only)
This command is a query and therefore not assigned a *RST value. The numeric suffixes <1|2> or
<1 to 8> are not significant for this command.
Содержание 1065.6000.20
Страница 3: ......
Страница 5: ......
Страница 17: ......
Страница 57: ...Contents Description of Commands FSE 1065 6016 12 I 6 4 E 16...
Страница 379: ...Contents Programming Examples FSE 1065 6016 12 I 7 2 E 1...
Страница 391: ......
Страница 393: ...Contents Maintenance and Instrument Interfaces FSE 1065 6016 12 I 8 2 E 15...
Страница 419: ......
Страница 421: ...Contents Error Messages FSE 1065 6016 12 I 9 2 E 1...
Страница 429: ......