FSE CONFigure-Subsystem
1065.6016.12
6.69
E-16
:CONFigure[:BTS]:POWer:STATic 0 to 6
This command defines the static power control level of the base station.
Example:
":CONF:POW:STAT 3
"
Features:
*RST value:
0
SCPI:
device-specific
Mode:
BTS
:CONFigure[:BTS]:POWer:DYNamic 0 to 15
This command defines the dynamic power control level of the base station.
Example:
":CONF:POW:DYN 5
"
Features:
*RST value:
0
SCPI:
device-specific
Mode:
BTS
:CONFigure[:BTS]:POWer:EXPected <numeric_value>
This command enters directly the rated output level of the base station specified by the
manufacturer.
Example:
":CONF:POW:EXP 43DBM
"
Features:
*RST value:
46 dBm (P-GSM phase I/II, E-GSM, R-GSM)
43 dBm (DCS1800, PCS1900)
SCPI:
device-specific
Mode:
BTS
:CONFigure[:BTS]:POWer:LIMit <numeric_value>
This command defines the level for the selection of level-dependent limit lines.
Example:
":CONF:POW:LIM 65DBM"
Feature:
*RST value:
depending on standard
SCPI:
device-specific
Mode:
BTS
This command is only available for the setting
:CONFigure[:BTS]:POWer:COUPled OFF
.
:CONFigure[:BTS]:POWer:SINGle[:STATe] ON | OFF
This command switches single measurement of carrier power on and off.
Example:
":CONF:POW:SING ON"
Feature:
*RST value:
OFF
SCPI:
device-specific
Mode:
BTS
Содержание 1065.6000.20
Страница 3: ......
Страница 5: ......
Страница 17: ......
Страница 57: ...Contents Description of Commands FSE 1065 6016 12 I 6 4 E 16...
Страница 379: ...Contents Programming Examples FSE 1065 6016 12 I 7 2 E 1...
Страница 391: ......
Страница 393: ...Contents Maintenance and Instrument Interfaces FSE 1065 6016 12 I 8 2 E 15...
Страница 419: ......
Страница 421: ...Contents Error Messages FSE 1065 6016 12 I 9 2 E 1...
Страница 429: ......