FSE CONFigure-Subsystem
1065.6016.12
6.83
E-16
:CONFigure[:MS]:NETWork[:TYPE] PGSM | PGSM900 | EGSM |EGSM900 | DCS |GSM1800 |
PCS|GSM1900 | RGSM | RGSM900 | GSM850
This command selects the standard type according to which the mobile will work.
Example:
":CONF:NETW DCS"
Features:
*RST value:
GSM
SCPI:
device-specific
Mode:
MS
:CONFigure[:MS]:NETWork:PHASe 1 | 2 [,PLUS]
This command selects the phase of the standard according to which the mobile will work.
Example:
":CONF:NETW:PHAS 2"
Features:
*RST value:
1
SCPI:
device-specific
Mode:
MS
:CONFigure[:MS]:TXSupp ON | OFF
This command defines that an additional carrier suppression of min. 20dB is taken into account for
the measurement. If there is already suppression, a more sensitive setting of the instrument is
selected.
Example:
":CONF:TXS ON"
Features:
*RST value:
OFF
SCPI:
device-specific
Mode:
MS
For measurements in the RX-band the value is automatically set to ON.
:CONFigure[:MS]:PRESet
This command resets the parameters for the standard selected to their default values (DEFAULT
SETTINGS).
Example:
":CONF:PRES"
Features:
*RST value:
--
SCPI:
device-specific
Mode:
MS
This command is an event and has thus no query and no *RST value assigned.
Содержание 1065.6000.20
Страница 3: ......
Страница 5: ......
Страница 17: ......
Страница 57: ...Contents Description of Commands FSE 1065 6016 12 I 6 4 E 16...
Страница 379: ...Contents Programming Examples FSE 1065 6016 12 I 7 2 E 1...
Страница 391: ......
Страница 393: ...Contents Maintenance and Instrument Interfaces FSE 1065 6016 12 I 8 2 E 15...
Страница 419: ......
Страница 421: ...Contents Error Messages FSE 1065 6016 12 I 9 2 E 1...
Страница 429: ......