OUTPut Subsystem FSE
1065.6016.12
6.144
E-16
:OUTPut<1|2>AF:SENSitivity <numeric_value>
This command changes the sensitivity of the AF-output.
Parameter:
<numeric_value> ::=
0.1 PCT to 100 PCTfor AM
0.1 KHZ to 100 KHZfor FM
0.0 1RAD to 10 RADfor PM
Example:
":OUTP:AF:SENS 20PCT"
Features:
*RST value:
100 % for AM
100 kHz for FM
10 rad for PM
SCPI:
device-specific
Mode:
VA-A