
CONFigure-Subsystem FSE
1065.6016.12
6.88
E-16
:CONFigure:SPURious:RANGe TXBand | OTXBand | RXBand | IDLeband | COMBined
This command selects the frequency range used for the measurement.
Example:
":CONF:SPUR:RANG OTX"
Features:
*RST value:
TXB
SCPI:
device-specific
Modes:
BTS, MS
TXBand
TX-Band
OTXBand
Not TX-Band
RXBand
RX-Band (option FSE-K11 only)
IDLeband
Idle band (option FSE-K10 only)
COMBined
TX-Band
±
2 MHz (option FSE-K11 only)
:CONFigure:SPURious:STEP<1 to 26> ON | OFF
This command selects a subband of the selected band for a spurious measurement.
Each band is divided up into 1 to max. 26 subbands, which are selected by the numerical suffix
following STEP. A subband is selected for measurement by setting ON.
Example:
":CONF:SPUR:STEP24 ON"
Feature:
*RST value:
ON
SCPI:
device-specific
Mode:
BTS, MS
:CONFigure:SPURious:STEP:COUNt?
This command queries the number of subbands of the currently selected band for a spurious
measurement.
Example:
":CONF:SPUR:STEP:COUNT?"
Feature:
*RST value:
-
SCPI:
device-specific
Mode:
BTS, MS
This command is a query and has therefore no *RST value assigned.
:CONFigure:SPURious:ANTenna CONDucted | RADiated
This command selects the features of the measurement of spurious emmissions.
Example:
":CONF:SPUR:ANT RAD"
Feature:
*RST value:
COND
SCPI:
device-specific
Mode:
MS
Содержание 1065.6000.20
Страница 3: ......
Страница 5: ......
Страница 17: ......
Страница 57: ...Contents Description of Commands FSE 1065 6016 12 I 6 4 E 16...
Страница 379: ...Contents Programming Examples FSE 1065 6016 12 I 7 2 E 1...
Страница 391: ......
Страница 393: ...Contents Maintenance and Instrument Interfaces FSE 1065 6016 12 I 8 2 E 15...
Страница 419: ......
Страница 421: ...Contents Error Messages FSE 1065 6016 12 I 9 2 E 1...
Страница 429: ......