CONFigure-Subsystem FSE
1065.6016.12
6.82
E-16
:CONFigure[:MS]:POWer:SINGle[:STATe] ON | OFF
This command switches single measurement of carrier power on and off.
Example:
":CONF:POW:SING ON"
Feature:
*RST value:
OFF
SCPI:
device-specific
Mode:
MS
:CONFigure[:MS]:POWer:SINGle:CLEar
This command clears the table containing the single-step carrier power measurements.
Example:
":CONF:POW:SING:CLE"
Feature:
*RST value:
--
SCPI:
device-specific
Mode:
MS
This command is an event and has therefore neither *RST value nor query.
:CONFigure[:MS]:POWer:SMALl ON | OFF
This command switches the limits for spurious measurement in the RGSM range. It is only available
for phase 2+.
Example:
":CONF:POW:SMAL ON"
Feature:
*RST value:
OFF
SCPI:
device-specific
Mode:
MS
:CONFigure[:MS]:CHANnel:SFH ON | OFF
This command switches slow-frequency hopping on or off.
Example:
":CONF:CHAN:SFH ON"
Feature:
*RST value:
OFF
SCPI:
device-specific
Mode:
MS
:CONFigure[:MS]:CHANnel:TSC 0 to 7
This command selects the midamble used by the mobile.
Parameter:
0 to 7
(training sequence for the Normal Burst)
Example:
":CONF:CHAN:TSC 3"
Features:
*RST value:
0
SCPI:
device-specific
Mode:
MS
Содержание 1065.6000.20
Страница 3: ......
Страница 5: ......
Страница 17: ......
Страница 57: ...Contents Description of Commands FSE 1065 6016 12 I 6 4 E 16...
Страница 379: ...Contents Programming Examples FSE 1065 6016 12 I 7 2 E 1...
Страница 391: ......
Страница 393: ...Contents Maintenance and Instrument Interfaces FSE 1065 6016 12 I 8 2 E 15...
Страница 419: ......
Страница 421: ...Contents Error Messages FSE 1065 6016 12 I 9 2 E 1...
Страница 429: ......