CONFigure-Subsystem FSE
1065.6016.12
6.70
E-16
:CONFigure[:BTS]:POWer:SINGle:CLEar
This command clears the table containing the single-step carrier power measurements.
Example:
":CONF:POW:SING:CLE"
Feature:
*RST value:
--
SCPI:
device-specific
Mode:
BTS
This command is an event and has therefore neither *RST value nor query.
:CONFigure[:BTS]:CHANnel:SLOT 0 to 7
This command selects the slot number within a transmission frame of the base station.
Example:
":CONF:CHAN:SLOT 3
"
Features:
*RST value:
0
SCPI:
device-specific
Mode:
BTS
On changing the slot number, the number of the midamble (TSC) is automatically adapted to the slot.
:CONFigure[:BTS]:CHANnel:SLOT:AUTO ONCE
This command automatically searches for the slot number within a transmission frame of the base
station. This requires only one slot to be active.
Example:
":CONF:CHAN:SLOT:AUTO ONCE
"
Features:
*RST value:
--
SCPI:
device-specific
Mode:
BTS
This command is an event and thus has no query and no *RST value assigned.
:CONFigure[:BTS]:CHANnel:SFH ON | OFF
This command defines whether the base station uses slow frequency hopping or not.
Example:
":CONF:CHAN:SFH ON
"
Features:
*RST value:
OFF
SCPI:
device-specific
Mode:
BTS
This command is available only when spurious or transient spectrum measurement is selected. The
settings for spurious measurement are independent from those selected for transient spectrum.
Содержание 1065.6000.20
Страница 3: ......
Страница 5: ......
Страница 17: ......
Страница 57: ...Contents Description of Commands FSE 1065 6016 12 I 6 4 E 16...
Страница 379: ...Contents Programming Examples FSE 1065 6016 12 I 7 2 E 1...
Страница 391: ......
Страница 393: ...Contents Maintenance and Instrument Interfaces FSE 1065 6016 12 I 8 2 E 15...
Страница 419: ......
Страница 421: ...Contents Error Messages FSE 1065 6016 12 I 9 2 E 1...
Страница 429: ......