ULTRATWIN (UL)
INSTRUCTION MANUAL
96
Ratiometric
If the flow calculation is to be
ratiometric P702 = 2
the flow will be
calculated using the formula: q= q
cal
C
e
/C
ecal
(h
e
/h
ecal
)
1.5
Where:
q = flowrate
q
cal
=
flowrate at maximum head P705
Ce
=
discharge coefficient
calculated by UltraTWIN
P723
Ce
cal
= discharge coefficient at maximum head
he = effective head
he
cal
= effective head at maximum head